The short answer
Most drip emitters, sprayers and inline dripline call for filtration of at least 120 mesh, and many systems use 150 mesh for extra protection. Drip tape and some very low-flow products commonly need finer filtration, around 150–200 mesh. Always check the emitter or dripline manufacturer’s recommendation, since that’s what their warranty is usually based on.
Every drip system needs a filter, even on clean city water. Emitter passages are small, and it only takes a few grains of sand or flakes of pipe scale to block one.
What mesh size means
Mesh number is the number of openings per linear inch of screen. A higher mesh number means a finer screen that catches smaller particles. Microns measure the size of the openings directly (1 micron = 0.001 mm).
Approximate equivalents (exact values vary with wire thickness and manufacturer):
| Mesh | Approximate opening (microns) |
|---|---|
| 80 | about 180 |
| 100 | about 150 |
| 120 | about 125 |
| 140–150 | about 100–105 |
| 200 | about 75 |
Recommended mesh by emitter type
| Device | Typical minimum filtration |
|---|---|
| Sprinkler spray heads and rotors | around 80 mesh |
| Drip emitters, micro-sprayers and inline dripline | around 120 mesh (150 common) |
| Drip tape | around 150–155 mesh or finer |
If one system feeds both sprinklers and drip, filter for the finest device on it.
Match the filter to your water source
- Municipal water: usually clean. A modest screen filter at the faucet acts mainly as insurance against occasional sediment or debris after main repairs.
- Well water: may carry sand or silt. A screen filter with more surface area is often needed. Where sand is heavy, a sand separator ahead of the screen helps.
- Ponds, rain barrels, tanks and ditches: often carry algae, organic matter and fine debris. Disc filters, or larger filters with more screen area, handle this better. Very dirty water may need staged filtration, with a coarse screen first and a finer one after.
The dirtier the water, the more filter surface area you want. A small filter on dirty water can clog within days, while a larger one may go weeks between cleanings.
Filter element types
- Screen filters use a cylindrical mesh screen. They’re inexpensive, easy to clean and good for sand, silt and particles. Organic slime and algae can smear across the screen and clog it quickly.
- Disc filters use a stack of grooved plastic discs, which trap particles through the depth of the stack. They handle algae and organic material better than screens and hold more debris before clogging. Cleaning usually means separating and rinsing the discs.
- Media (sand) filters pass water through a tank of graded sand or similar media. They’re used mainly in farm and larger systems with heavily contaminated surface water, often with backflushing.
- Sand separators (hydrocyclones) spin water so heavy particles like sand drop out. They’re often used ahead of a screen or disc filter on sandy well water, and they don’t remove light organic material.
Filter body styles
- Inline (hose) filters: compact and cheap, good for small, clean-water systems. The screen is often harder to reach, since you may have to disconnect the filter to clean it.
- Y filters: the screen sits in an angled leg with a cap, so it’s easy to remove. Many have more screen area and go longer between cleanings than inline types.
- T filters: water enters the side of the body. They’re compact in height, which helps where faucet clearance is tight.
- Canister filters: a larger housing with an easy-access screen, good for medium home systems.
At an outdoor faucet, a full head assembly of timer, backflow preventer, filter, pressure regulator and tubing adapter takes up vertical space. Measure the clearance between the faucet and the ground before choosing parts.
Sizing a filter for flow
Filters are rated for a maximum flow, often in GPM, and cause some pressure loss that rises as they clog. Pick a filter rated for at least your zone’s flow, preferably with room to spare. An undersized filter loses more pressure and clogs faster.
Add up your zone flow first (see how to size a drip irrigation system), then compare it with the filter’s rating. If you have little pressure to spare, such as on a gravity system, choose a larger filter for its lower pressure loss (see gravity-fed drip irrigation).
Where the filter goes
A typical faucet-connected drip head assembly runs in this order:
- Timer or valve (if used)
- Backflow preventer
- Filter
- Pressure regulator
- Adapter to drip tubing
Placing the filter before the regulator protects the regulator from debris too. Many hose-thread filters and regulators aren’t rated for constant pressure, so they need to go after the timer or valve, not on the always-pressurized side. Systems with valves on a manifold, especially on dirty water, often need a larger filter ahead of the valves to protect them. If you inject fertilizer, inject upstream of the filter where practical (see venturi injectors for drip fertigation).
Cleaning and maintenance
- Check the screen regularly. Monthly is a reasonable starting point for clean water, and more often for dirty water or early in the season.
- Watch pressure. Gauges before and after the filter show the pressure drop across it. A rising difference means it’s time to clean. Falling pressure at the emitters can also point to a clogged filter (see drip irrigation operating pressure).
- Rinse screens and discs with clean water and a soft brush. Replace damaged screens and worn seals.
- Flush the lines. Fine particles that pass the filter settle at the ends of laterals. Opening end caps or flush valves periodically clears them.
- Winterize. In freezing climates, drain the filter housing or bring it indoors.
What a filter can’t fix
Filters stop particles, not dissolved substances. Some clogging problems need a different approach:
- Iron and manganese: dissolved in well water, they can turn into solid deposits and slime once exposed to air in the lines.
- Bacterial slime and algae: can grow inside lines and emitters, especially with warm water, sunlight or nutrient-rich water.
- Hard water scale: calcium and magnesium deposits can build up at emitter outlets.
If you see recurring clogging with a clean filter, a water test is a good next step. Treatment options vary, so consult the emitter manufacturer, a water-treatment professional or your local extension service before adding chemicals to an irrigation system.
Clogging shows up as uneven emitter output. A simple way to check for it is the catch-cup test in drip uniformity coefficient.