Drip System Design

Uniformity Coefficient in Drip Irrigation: What It Means and How to Measure It

What the uniformity coefficient means for drip irrigation, how CU, DU and emission uniformity are calculated, and a simple catch-cup test for home systems.

On this page
  1. What “uniformity” means in a drip system
  2. The main uniformity measures
  3. How to measure uniformity in your own drip system
  4. Worked example
  5. What counts as a good result?
  6. Common causes of poor uniformity
  7. How to improve uniformity
  8. Uniformity vs. efficiency

What “uniformity” means in a drip system

Uniformity describes how evenly a system delivers water. In a perfect drip system, every emitter would release exactly the same amount. In real systems, emitters vary because of manufacturing differences, pressure changes along the line, elevation, and partial clogging.

Uniformity matters because you have to set run times for the driest plants. If some emitters put out 30% less than others, you either accept underwatered plants or run the zone longer and overwater everything else. That’s why poor uniformity quietly wastes water even when there are no visible leaks.

A uniformity coefficient turns that variation into a single percentage. The closer to 100%, the more even the delivery.

The main uniformity measures

Several measures are in common use, and they give different numbers for the same data, so it helps to know which one you’re looking at.

Christiansen’s uniformity coefficient (CU)

Developed for sprinkler testing, CU compares each reading with the average:

CU = 100 × [1 − (sum of |each reading − average|) ÷ (number of readings × average)]

In plain terms, it’s 100% minus the average deviation expressed as a percentage of the mean. CU is used for drip as well as sprinklers, especially in research.

Low-quarter distribution uniformity (DU) and emission uniformity (EU)

This measure focuses on the plants getting the least water:

DU = 100 × (average of the lowest 25% of readings) ÷ (average of all readings)

For drip systems, the same low-quarter calculation on emitter flows is usually called field emission uniformity (EU). It’s the measure most often used in practical drip evaluations, because it shows directly how much the driest quarter of the system lags behind the average.

Low-quarter DU or EU is normally lower than CU for the same data, since it’s driven by the worst readings.

Manufacturer’s coefficient of variation (Cv)

This number describes a product, not your system. Cv is the standard deviation of flow from a sample of new emitters, divided by their mean flow, tested at constant pressure. A lower Cv means more consistent emitters. Product literature often classifies emitters roughly like this (based on ASABE engineering practice for point-source emitters):

Manufacturer’s Cv Commonly used classification
under 0.05 good
0.05–0.07 average
0.07–0.11 marginal
0.11–0.15 poor
over 0.15 unacceptable

A low Cv emitter can still perform unevenly in a badly designed system, but a high Cv emitter limits how good your system can be.

How to measure uniformity in your own drip system

You don’t need lab equipment. You need:

  • Several identical cups or small containers
  • A measuring cup or graduated cylinder marked in millilitres
  • A timer
  • A notebook

Choose sample points. A standard field approach samples emitters at four positions along a zone’s supply: near the inlet, about one-third along, about two-thirds along, and at the far end. It does this on several laterals, usually 16 or more emitters in total. In a small garden, aim to include the first and last emitters on each line and any emitters uphill or farthest from the water source.

Steps:

  1. Run the zone for several minutes until all lines are full and pressure has stabilized.
  2. Place a cup under each chosen emitter at the same moment, or work in a consistent order with a fixed timing.
  3. Collect for a fixed time, such as one or two minutes.
  4. Measure each cup in millilitres and record it with its location.
  5. Calculate CU and low-quarter DU/EU.

To convert readings to flow, millilitres per minute × 0.0159 = GPH, and millilitres per minute × 0.06 = L/h. Our guide to calculating drip rate has more detail on measuring individual emitters.

Worked example

Eight emitters, each caught for one minute, gave these readings in millilitres:

62, 60, 64, 58, 61, 55, 63, 57

  • Average: 480 ÷ 8 = 60 ml
  • Lowest quarter: the 2 lowest readings, 55 and 57, average 56 ml
  • Low-quarter DU/EU: 56 ÷ 60 × 100 ≈ 93%
  • Deviations from the average: 2, 0, 4, 2, 1, 5, 3, 3, which sum to 20
  • CU: 100 × (1 − 20 ÷ (8 × 60)) = 100 × (1 − 0.042) ≈ 96%

Both values are high, and as expected, DU comes out a little lower than CU. With 60 ml a minute as the average, these emitters are delivering about 0.95 GPH, close to a 1 GPH rating.

What counts as a good result?

Rating ranges vary by source and method, so treat these as rough guides. For field emission uniformity in drip systems, guidance commonly cited from ASABE practice is:

  • 90% or higher: excellent
  • 80–90%: good
  • 70–80%: fair
  • Below 70%: poor

New, well-designed drip systems are generally expected to land in the upper ranges. Note that sprinkler DU benchmarks, like those used for lawns, are much lower because overlapping spray patterns are harder to make even. Don’t compare a drip result against sprinkler targets.

Common causes of poor uniformity

  • Pressure differences. Long runs, high flow per line and undersized tubing lose pressure toward the end. See maximum run length for 1/2-inch drip tubing and drip irrigation operating pressure.
  • Elevation changes. Non-PC emitters put out more at the bottom of a slope and less at the top. See designing drip irrigation for slopes.
  • Clogging. Sediment, algae, bacterial slime and mineral deposits partially block emitters. Look for low readings scattered randomly rather than in a pattern.
  • Mixed emitters. Different brands, flow rates or PC and non-PC emitters on the same zone.
  • Leaks and damaged fittings. These steal pressure from everything downstream.
  • Drain-down. After shut-off, low emitters keep draining the line, adding extra water at the low end.

The pattern of low readings helps with diagnosis. Readings that fall steadily toward the far end suggest friction loss. Low readings at high points suggest elevation. Random low readings suggest clogging.

How to improve uniformity

Uniformity vs. efficiency

Uniformity and efficiency are related but not the same. Uniformity measures how evenly water is delivered. Efficiency measures how much of the applied water ends up useful to the plants. A system can be very uniform and still waste water if it runs too long. Poor uniformity, however, almost always lowers efficiency, because you end up overwatering to satisfy the driest spots. For more on that, see what is the efficiency of drip irrigation.

The complete guide to drip system design

How to Size a Drip Irrigation System: Flow, Water Needs and Capacity
Read the guide

Keep exploring

Guides from other topics

All topics →