The short answer
In drip irrigation, the drip rate is the flow from an emitter, usually expressed in gallons per hour (GPH) or litres per hour (L/h). You can calculate it by catching the water from one emitter for a set time and measuring it:
Drip rate (GPH) = millilitres collected per minute × 0.0159
Drip rate (L/h) = millilitres collected per minute × 0.06
For example, if an emitter fills a cup with 63 ml in one minute, it’s delivering about 1 GPH (about 3.8 L/h).
This article covers drip rate in drip irrigation. IV infusion drip rates are a separate medical calculation and are not covered here.
How to measure an emitter’s drip rate
You’ll need a small cup, a measuring jug or graduated cylinder marked in millilitres, and a timer.
- Run the zone for a few minutes so the lines are full and pressure has settled.
- Hold or place the cup under the emitter and start the timer.
- Collect for exactly 1 minute. For very low-flow emitters, collect for 2–5 minutes and divide by the number of minutes.
- Measure the volume in millilitres.
- Convert using the formulas above.
To check a whole line, repeat at the first emitter, one in the middle and the last emitter. If the results differ a lot, see drip uniformity coefficient for a more formal test.
Where do the constants come from? One US gallon is about 3,785 ml. One ml per minute is 60 ml per hour, which is 60 ÷ 3,785 ≈ 0.0159 GPH, or 0.06 L/h.
Conversion table: millilitres per minute to GPH and L/h
| Collected in 1 minute | Approximate GPH | Approximate L/h |
|---|---|---|
| 32 ml | 0.5 | 1.9 |
| 33 ml | 0.53 | 2.0 |
| 63 ml | 1.0 | 3.8 |
| 67 ml | 1.06 | 4.0 |
| 126 ml | 2.0 | 7.6 |
| 133 ml | 2.1 | 8.0 |
| 252 ml | 4.0 | 15.1 |
US emitters are usually labelled 0.5, 1, 2 or 4 GPH. Metric emitters are often labelled 2, 4 or 8 L/h, which are close to, but not exactly, the same.
Calculating drip rate for dripline and drip tape
Inline dripline and drip tape are often rated by total flow per length rather than per emitter.
From GPM per 100 feet (common for drip tape):
GPH per emitter = (GPM per 100 ft × 60) ÷ number of emitters per 100 ft
Example: tape rated 0.45 GPM per 100 ft with 12-inch spacing (100 emitters per 100 ft): 0.45 × 60 ÷ 100 = 0.27 GPH per emitter.
From GPH per 100 feet: divide by the number of emitters in 100 feet.
Metric dripline (L/h per emitter at a given spacing): to get flow per metre, divide the emitter flow by the spacing in metres. For example, 2 L/h emitters at 0.3 m spacing deliver about 2 ÷ 0.3 ≈ 6.7 L/h per metre of line.
Calculating the drip rate of a whole zone
A zone’s total flow is the sum of all its emitters:
Zone flow (GPH) = number of emitters × GPH per emitter
Example: 40 emitters at 1 GPH plus 20 at 2 GPH = 40 + 40 = 80 GPH, or about 1.3 GPM.
That number matters for checking your water supply and tubing limits. See how to size a drip irrigation system and maximum run length for 1/2-inch drip tubing.
Turning drip rate into an application rate
For beds with evenly spaced emitters, you can express drip rate as a depth of water per hour, like rainfall:
Application rate (in/hr) = 231 × GPH ÷ (emitter spacing in inches × row spacing in inches)
Metric (mm/hr) = L/h ÷ (emitter spacing in m × row spacing in m)
Example: 0.5 GPH emitters every 12 inches, rows 12 inches apart: 231 × 0.5 ÷ 144 ≈ 0.8 in/hr.
Metric example: 2 L/h emitters at 0.3 m in rows 0.4 m apart: 2 ÷ (0.3 × 0.4) ≈ 16.7 mm/hr.
Using drip rate to set run times
Once you know how much water a plant needs per watering and how fast its emitters deliver, the run time follows:
Run time (hours) = gallons needed ÷ total GPH reaching that plant
Example: a shrub that needs about 4 gallons per watering, with two 1 GPH emitters (2 GPH total), needs about 2 hours.
Because one zone serves every plant on it, choose emitter counts and flow rates so plants with similar needs reach their target in about the same run time. Our article on how many drip emitters per tree or shrub covers this balancing act. For estimating how much water plants need in the first place, see how to calculate irrigation.
Why measured drip rate differs from the label
- Pressure. Non-pressure-compensating emitters deliver more above their rated pressure and less below it. See drip irrigation operating pressure.
- Position on the line. Friction and elevation reduce pressure at the far end or high points.
- Clogging. Partial blockages from sediment, algae or minerals reduce flow, often unevenly.
- Manufacturing variation. Even new emitters vary a little from one to the next.
- Measurement error. Splashing, timing or reading small volumes can throw results off. Longer collection times improve accuracy.
Measuring a few emitters each season is a quick way to catch problems before plants show stress.